Untitled

The side panels can be constructed out of acrylic or anti-static vinyl sheet as per customer’s requirements. The High Efficiency Particulate Air (HEPA) filter ensures an efficiency of filtering 99.99% of 0.3μm or larger particles. The resulting laminar flow also restricts any contaminating particles present to the streamlines thus ensuring minimum contamination.

Untitled

For more stringent requirement, Ultra Low Penetration Air (ULPA) filter achieves a rate of 99.9999% of 0.12μm or larger particles .

CLEAN BOOTHS create a clean environment of a higher level of cleanliness within a clean room area.

It is complete with HEPA filter module mounted on ceiling structure for downward vertical clean air flow.

Untitled

  • Easy installation and relocation
  • Capable of achieving Class 10 to Class 100,000 cleanliness
  • Frameworks can be epoxy finished steel, aluminum or stainless steel
  • Custom made size is available

Cleanroom Total Solution

ESD Heavy-duty Homogeneous Vinyl Sheet/Tile Flooring

Epoxy Flooring

  • ESD Epoxy Self-Leveling
  • Epoxy Coating
  • Chemical Resistance Epoxy Coating
  • Epoxy Mortar System

Polyurethane Coating

22962BA6 8867 4FD6 A7E4 D5E81954150B

Air Filter

Primary, Secondary & HEPA/ULPA Filters

47B08606 4421 4754 B88C 2B3F5243D803

Fan Filter Units (HEPA / ULPA)

ABCD6D24 F333 426A 97DF 58484023BEB8

Services

ISO 5 or CLASS 100 CLEANROOM

Built accordance to Federal Standard, Class 100 Cleanroom Facility, equivalent to ISO 14644-1, ISO 5

System Advantages:

Class 100 or Class 5 means that less than 100 particles (0.5 micron in size) per cubic foot or 3,520 particles are present in per cubic meter – limits the airborne particles equal or greater than 0.5 microns

37C2ACF2 493B 416B 95A8 4CA3CE48268A

Untitled

Unidirectional Flow which allows single direction of flow of uniform speed range between 60 – 90 fpm throughout the entire space.

Pressurisation is always positive to ensure that no cross contamination on particles from outside the cleanroom once the doors are properly closed.

161914D3 9091 410B 8DF9 91E1DF39AB5B

Untitled

Room are constructed using smooth, monolithic, cleanable, chip resistant materials with a minimum of joints and seams & no crevices.

Raised floor system to allow vertical air flow system & uni-directional flow is achievable. Air can flow through perforated panels & can be exhausted in a sub-floor area.

Untitled

Heavy duty ceiling works to ensure servicing and installation of Fan Filter Units acheivable with gaskets around the frameworks to minimise the leakages.

ISO 8 or CLASS 100,000 CLEANROOM

Built accordance to Federal Standard, Class 100,000 Cleanroom Facility, equivalent to ISO 14644-1, ISO 8

System Advantages:

Class 100,000 or Class 8 means that less than 100,000 particles (0.5 micron in size) per cubic foot or 3,520,000 particles are present in per cubic meter – limits the airborne particles equal or greater than 0.5 microns

C9F245B1 7C55 42DD A672 E8E07827B5B7

Untitled

Non-Unidirectional Flow which create turbulence air flow patterns, multiple pass circulation and by dilution and eliminate settling of particles with low level return system.

Pressurisation is always positive to ensure that no cross contamination on particles from outside the cleanroom when the doors are properly closed.

13F45862 22E4 410D 8A61 3361819B65EC